Reflectance at 850nm, 905nm, 940nm and 1550nm
The 410-LIDAR measures reflectance simultaneously at four key wavelengths employed by lidar systems. Collect measurements on materials and objects that cannot easily be brought into the lab. Fast calibration and measurement times without sacrificing measurement accuracy and repeatability. Option to customize wavelengths.
Applications
Reflectance data from 410-Lidar for the following applications:
Easy Operation
The 410-LIDAR touchscreen interface provides guided calibration, sample identification, and measurement data display.
More Information
Measured Parameter |
Directional hemispherical reflectance (DHR) |
Method |
Integrated total reflectance in a band for a given angle of incidence |
Measured Value |
Absolute reflectance (0-1) |
Calculated Value |
Total reflectance, absorptance |
Wavelength Bands (microns) |
850nm, 905nm, 940nm and 1550nm |
Angle of Incidence |
20º from normal incidence |
Calibration Coupon |
Glazed Ceramic |
Accuracy |
+/- .02 |
Repeatability |
± .005 units |
Beam Spot Size |
0.50 inches |
Measurement Time |
7 sec |
Sample Size & Geometry |
Flat: ≥ 0.5 in. diameter Curved: 6 in. convex; 12 in. concave |
Warm Up Time |
90 seconds |
Time Between Measurements |
2 seconds |
Sample Temperature |
Ambient or heated/cooled to 0 – 100º C |
Operating Temp |
0º to 40º C |
Storage Temp |
-25º to 70ºC |
Run Time |
2 hours on one battery. Battery easily replaced with continuous operation after battery replacement. |
Power Source |
Rechargeable battery (standard environmentally friendly NiMH) |
Battery Recharge Time |
1 hour |
IR Source |
Kanthal filament operated at about 1,000ºC |
Weight |
4.7 lb |
Form Factor |
H 11.54”, L 9.04”, W 3.27” (29.31 cm x 22.96 cm x 9.44 cm) |
Operator Interface |
LCD graphics screen, 1/4 VGA, touch screen, software buttons; trigger switch in handle |
Diagnostics |
On screen status and signals monitor. Signal values stored with data. Raw data collection and display. |
Data Format |
Data files can be opened and post processed with Excel or a text processor |
Data Storage |
Removable SanDisk (SD) card |
Export Control |
ECCN #3A999.F |
Standard 410-LiDAR Components
- Command Module with safety strap
- 410-LIDAR Measurement Head with port cap
- Glazed Ceramic Calibration coupon in storage container (Non-NIST traceable)
- SecureDigital card reader on a USB cable
- SecureDigital card for data storage, 4 GB
- 410-LIDAR operating software
- 12 Volt battery cartridge – 2 batteries total
- Battery charger
- Pelican Case shipping/storage container
- Accessories container
- 1-year warranty
- Worldwide support
Optional 410-LIDAR Components
- Benchtop Remote Control Unit – 220VAC
- Benchtop Remote Control Unit – 120VAC
- Handheld Command Module – 220VAC
- Glazed Calibration Coupon (NIST Traceable)
- 410-Series Reflectometer Maintenance and Calibration Plan (Non-NIST)
- 410-Series Reflectometer Maintenance and Calibration Plan (NIST)
- SOC 410 LIDAR Extended Warranty
- SD Card for Extra Data Storage